To complete the remaining fields, refer to the figure and table that corresponds to your mode. Device Clock Time Displays the time on the switch, obtained from the time source. Grandmaster Selection Priority1 Type a value to override the default criteria clock quality, clock class, and so on for the best master clock selection.
A lower value takes precedence. Type the recommended to connected devices to send delay request messages when the switch port is in the master state. Grandmaster Selection Type a value to override the default criteria clock quality, clock class, and so on for the best master clock selection. A lower value takes Priority1 precedence. Values are defined from 0… with 0 as the best clock. Accuracy Indicates the expected absolute accuracy of the local clock relative to CIP Sync time synchronization epoch 31 December, For a list of switches that Topology support a DLR topology, see Stratix switches support as many as three rings per switch.
For more information about End to End Transparent Page Configure Switch Features Chapter 3 Figure 11 shows an example of a switch configured for redundant gateway. All ports are assigned to VLAN 1. Page Configure Switch Features Chapter 3 You can configure redundant gateways on switches that are either ring supervisors or ring nodes. In this example, the switch provides redundant gateway functionality, so that all ring nodes have access to the outside network. From the Configure menu, choose DLR.
Stratix switches only. To configure the switch as a ring node or a ring supervisor, complete the Default: Disabled Port1 Choose a ring port. To add IP addresses individually, click Add Entry. Field Description Index Port 1 Choose a ring port. You assign the precedence value on the Advanced Network Configuration dialog box.
Beacon Timeout Type the amount of time ring nodes wait before timing out in the absence of received beacon messages. The switch transmits the precedence value is advertise messages and is used to select the redundant gateway when multiple redundant gateways are configured.
A higher value means higher precedence. Page Chapter 3 Configure Switch Features 2. This pool must be previously configured as described on page If a device leaves and then rejoins the network, the device receives the next available IP address, which is not necessarily the same address that it had before.
Configure the DHCP server. Configure the IP address pool. Assign an IP address to a switch port. Click Add. Complete the fields and click OK. The name can have up to 31 alphanumeric characters. The name cannot contain a? The format is a bit numeric address that is written as four numbers that are separated by periods.
Click New Pool. Page Chapter 3 Configure Switch Features 3. Complete the fields and click Close. DUAL allows all devices that are involved in a topology change to synchronize simultaneously. Routers that are not affected by topology changes are not involved in recomputations. Valid values: 1… where is percent loading Type the smallest allowed value for the maximum transmission unit MTU in bytes. Auto-Summary Check the checkbox to allow the automatic summarization of subnet routes into network-level routes.
This feature is disabled by default the software sends subprefix routing information across classful network boundaries. Valid values: 1 or any positive number that is a multiple of Page Etherchannels Each EtherChannel can consist of up to eight compatible, configured Ethernet ports.
Complete the fields described in Table 55 and click OK. Description Type a description of the channel.
Administrative Check Enable to make the channel active. Clear Enable to make the channel inactive. Speed Choose the operating speed of the channel.
You can add, edit, and delete EtherChannel members. See Table 52 for the maximum number of EtherChannels available per switch. Feature mode provides efficient allocation of resources on the switch to support the operation of multiple, time-sensitive features. Page Gnss Considerations Clock mode, and three satellites are required for the first fix in Self-survey mode.
High-availability HSR is available on Stratix switches. To stack multiple switches, you connect the switches via as many as two uplink Ethernet ports per switch. You use the CLI to configure network ports as designated stack ports. If you enable only one macro, the QoS settings applied during Express Setup remain active. NetFlow Lite uses flows to provide statistics for accounting, network monitoring, and network planning.
A flow is unidirectional stream of packets that arrives on a source interface and has the same values for the keys. A NAT instance contains entries that define each address translation and other configuration parameters. The translations that you define depend on whether traffic is routed through a Layer 3 switch or router or a Layer 2 switch.
Stratix across NAT ports 1…6 and 13… Page Configure Switch Features Chapter 3 3. In the Name field, type a unique name to identify the instance. The instance name cannot include spaces or exceed 32 characters. Page Configure Switch Features Chapter 3 6. Click the Public to Private tab. Click Add Row, complete the fields, and click Save. We recommend that you use the default values.
Click the Advanced tab. In the navigation pane, click NAT. Range Type the number of addresses to include in the range. This address must correspond to the size of the subnet mask to translate. Page Chapter 3 Configure Switch Features 6. Click OK. Click New Entry to display the New Entry dialog box. Single is the default value. Configure the ports to assign to the instance. Page Configure Switch Features Chapter 3 4. You can select the same VLAN for multiple ports. Click Next to display the Translations view.
Page Chapter 3 Configure Switch Features 7. Configure translations for one device, a range of devices, or all devices on a subnet. NTP uses a two-way time transfer mechanism between a master and a slave.
NTP is capable of synchronizing devices in a tightly-controlled network. You can add multiple NTP servers. To add an association, follow these steps. To customize the default settings for an instance, see page If the network numbers in an area are contiguous, you can configure the ABR to advertise a summary route that covers all individual networks within the area that are in the specified range. Do not change the packet pacing timers unless all other options to meet OSPF packet flooding requirements have been exhausted.
Stratix and switches implement RedBox functionality. Page In this example, the Stratix switch is configured as a RedBox. However, you can use any switch as an infrastructure switch in a PRP system. A PRP channel group is a logical interface that aggregates two Gigabit Ethernet physical ports into a single link.
Configure a Stratix or as a RedBox as described on page Page Configure Switch Features Chapter 3 5. On each downlink port of the RedBox that connects to an end device, enable PortFast.
From the Configure menu, choose STP. Click the PortFast tab. This procedure does not apply to a Stratix or switch configured as a RedBox. Page Port Mirroring Configure Switch Features Chapter 3 Port Mirroring Port mirroring is for advanced users with experience in troubleshooting traffic and protocol issues on networks. Port mirroring copies, or mirrors, traffic on one port to a monitoring port where a network protocol analyzer tool can capture the packet.
From the Configure menu, choose Smartports. Browse Tech Doc Center. Search Literature Library. Get Answers. Stratix Fixed Managed Ethernet Switches. Chevron Up Chevron Up. Product Compatibility and Migration Solutions Demanding market conditions pose significant challenges.
Upload Configuration To upload configuration from the switch and save it on your computer, follow this pr … Basic authentication, compatible with POP servers, is supported, … Filters can be configured to capture packets from certain devices MAC addresses. You can also filter to capture packets with a certain destination address.
To enable port mirror, follow this procedure. Click Switch Configuration and Mirror Configuration to enable … See page 33 for a table of status codes.
Allen-Bradley Stratix Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Because of this difference … 2. You can now use the EMS switch in your program. See Appendix D for the data layout. This feature is useful when multiple EMS switches are installed.
The switch reports this name on … With power applied, push the reset button with a small screwdriver. Hold the button in for 30 seconds. Cycle power to complete the IP reset. Your IP address defaults to Change Settings to Default To change all settings back to default, use this procedure. Remove power. Push the reset button with a small screwdriver.